Epsilon Extensometers and COD gauges |
||||||||||||||||||||
Extensometer Epsilon 3442 Miniature Very small and rugged, yet ultra-light weight, these transducers are widely used for testing small and delicate samples. Ideal for many biomedical tests, as well as for wire and thin sheet materials. Also great for low cycle fatigue testing where short samples are used. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
• Adapter kits to change gauge lengths |
||||||||||||||||||||
Extensometer Epsilon 3542 General purpose extensometers for axial tensile, compression, and cyclic testing. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
• Quick attach kit wireforms for large specimens |
|
|||||||||||||||||||
Long gauge length extensometer Epsilon 3542L These transducers have been specially designed for long gage length applications where low level strain measurements are required. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Options: • Quick attach kit wireforms for large specimens
|
||||||||||||||||||||
Long gauge length extensometer Epsilon 3543 It is a uniquely designed unit that may be left on through specimen failure. These extensometers are widely used where long samples are required. They are ideal for testing steel re-bar, weld joints, and wire materials. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Options: • Quick attach kit wireforms for large specimens |
||||||||||||||||||||
Bi-axial or axial averaging extensometer Epsilon 3560 A single integral unit provides simultaneous lateral (transverse) strain and averaged axial strain measurement. The unit is also available as an averaged axial extensometer alone. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Options: • Connectors to interface to nearly any brand test equipment |
|
|||||||||||||||||||
High elongation extensometer Epsilon 3800 Designed for plastics, rubber and elastomer testing, these extensometers have very long measuring ranges. Their unique design allows testing to failure and minimizes interaction with the sample. Specification: • Gauge length:
• Measuring range:
• Temperature range:
• Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max. Options: • Can be provided with either:
• 2 mV/V output for use with electronics designed for strain gaged sensors |
|
|||||||||||||||||||
Laser non-contact extensometers Epsilon LE-05 and LE-15 These extensometers are high precision non-contacting units for strain measurement in materials testing. They use a high speed laser scanner to measure the spacing between reflective tape strips on the sample. Спецификация: • Measuring range:
• Resolution:
• Linearity:
• Repeatability:
• Scan Rate:
• Scan Line Orientation:
• Analog Output:
• Power Input: 220 VAC |
|