AC-07-XXXX Series Displacement Transducers
AC-07-XXXX series displacement transducers are compact and rugged yet light in weight. These units are widely used for testing materials such as advanced composites, metals and polymers. They can also be used to test round and flat specimens to perform tensile, compression and cyclic tests. These extensometers include circuitry for auto-calibration against internal shunt reference, thus obviating the need for on-site calibration during installation.
|
Стандартные характеристики:
• Full strain 350Ω bridge construction • Internal shunt reference for auto calibration* • Operational in both tension and compression modes • Easy mounting on to the specimen • Compatible with any strain gage electronics
|
Applications:
• Biomedical tests • Testing of wire and thin sheet materials • Tension, compression and cyclic testing on metal composites, high temperature and polymers • Compression testing on rock and concrete
|
Room Temperature Extensometer |
High Temperature COD Gage |
Diametral Extensometer |
Room Temperature COD Gage
|
High Temperature COD Gage
|
Averaging Extensometer |
Specification:
Excitation
|
5 VDC typical, 10 VDC or VAC max
|
Output
|
2.34 mV/V nominal depending on model
|
Linearity
|
<0.15% of full scale measuring range, depending on model
|
Temperature
|
0 to 1000 C
|
|
Room Temperature Axial Extensometers
|
|
High Temperature Axial Extensometers
|
Model No.
|
Gage length, mm
|
Measuring range, mm
|
Model No.
|
Gage length, mm
|
Measuring range, mm
|
AC-07-1005
|
12.5
|
+/-0.5
|
AC-07-1105
|
10
|
+/-1.25
|
AC-07-1010
|
12.5
|
+/-1
|
AC-07-1110
|
12.5
|
+/-1.25
|
AC-07-1015
|
12.5
|
+/-2.5
|
AC-07-1115
|
12.5
|
+/-1.5
|
AC-07-1020
|
12.5
|
+/-5
|
AC-07-1120
|
12.5
|
+/-2.5
|
AC-07-1025
|
12.5
|
6.25/-3.1
|
AC-07-1125
|
25
|
8/-2
|
AC-07-1030
|
25
|
12.5/-6.35
|
AC-07-1130
|
25
|
12.5/-2.5
|
AC-07-1035
|
25
|
6/-3
|
Room Temperature Diametral Extensometers
|
AC-07-1040
|
50
|
+/-12.5
|
Model No.
|
Measuring range, mm
|
AC-07-1045
|
50
|
25/-12.5
|
AC-07-3005
|
2-4
|
AC-07-1050
|
75
|
12.5/-6.5
|
AC-07-3010
|
4-8
|
AC-07-1055
|
25
|
+/-2.5
|
AC-07-3015
|
8-12
|
Room Temperature Averaging Extensometer
|
AC-07-3020
|
12-16
|
AC-07-2005
|
100
|
+/-12.5
|
Room temperature shear extensometer
AC-07-4005
|
AC-07-2010
|
50
|
+/-6
|
Room temperature shear extensometer
AC-07-4015
|
|
Room Temperature COD Gages
|
|
High Temperature COD Gages
|
Model No.
|
Gage length, mm
|
Measuring range, mm
|
Model No.
|
Gage length, mm
|
Measuring range, mm
|
AC-07-0005
|
5
|
2/-1
|
AC-07-0105
|
5
|
3/-1
|
AC-07-0010
|
5
|
3/-1
|
AC-07-0110
|
10
|
AC-07-0015
|
10
|
4/-1
|
|
AC-07-0020
|
10
|
7/-1
|
|
AC-07-0025
|
12
|
12/-2
|
|
|
* Shunt is a resistor which is connected to one arm of the full-bridge circuits, and when activated shunt simulates an output signal which accurately measured and displayed by software. The shunt allows to quickly and accurately calibrate all the BiSS transducers
**Custom options available
Room temperature extensometers and COD gages are rated for operating temperatures up to 800С
High temperature extensometers and COD gages are rated for operating temperatures up to 12000С